tutor
domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init
action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6121tutor-pro
domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init
action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6121woocommerce-direct-checkout
domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init
action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6121The only goal of all experts and professors in our company is to design the best and suitable study materials for all people. According to the different demands of many customers, they have designed the three different versions of the Fire-Inspector-II Study Materials for all customers. They sincerely hope that all people who use the Fire-Inspector-II study materials from our company can pass the exam and get the related certification successfully.
With the protection of content and learning methods on our Fire-Inspector-II study guide, you will not have to worry about your exam at all. Of course, if you have any suggestions for our Fire-Inspector-II training materials, you can give us feedback. Our team of experts will certainly consider your suggestions. Perhaps the next version upgrade of Fire-Inspector-II Real Exam is due to your opinion. In order to thank you for your support, we will also provide you with some benefits.
>> Exam Fire-Inspector-II Overviews <<
All kinds of exams are changing with dynamic society because the requirements are changing all the time. To keep up with the newest regulations of the Fire-Inspector-II exam, our experts keep their eyes focusing on it. And the Fire-Inspector-II study tool can provide a good learning platform for users who want to get the test Fire-Inspector-II Certification in a short time. If you can choose to trust us, I believe you will have a good experience when you use the Fire Inspector study guide, and you can pass the exam and get a good grade in the test Fire-Inspector-II certification.
NEW QUESTION # 84
Compressed natural gas (CNG) motor vehicle fuel-dispensing equipment may be installed in which of the following locations?
Answer: C
Explanation:
Compressed Natural Gas (CNG) motor vehicle fuel-dispensing equipment installation requirements are outlined in 2021 International Fire Code (IFC) Section 2208 - Compressed Natural Gas Motor Fuel- Dispensing Facilities.
IFC 2021, Section 2208.3 - Equipment Location and Protection:
Requires that CNG dispensing equipment be installed at least:
10 feet from property lines
20 feet from public streets, highways, sidewalks, or railroads
10 feet from buildings or structures
Why Other Options Are Incorrect?
A: 40 ft. from trolley wires.
The IFC does not specify a 40-ft requirement for trolley wires in relation to CNG fuel-dispensing equipment.
B: 15 ft. from a public street.
Incorrect because IFC 2208.3 states that the minimum required distance from a public street is 20 feet, not 15 feet.
D: 5 ft. from an undeveloped property line.
Incorrect, as the minimum clearance from any property line is 10 feet, not 5 feet.
NEW QUESTION # 85
According to the fire code, when compliance is not immediate, inspection reports of code violations must always include a description of the violation and which of the following?
Answer: A
Explanation:
When fire inspectors identify code violations, the inspection report must include a description of the violation along with a recommended corrective action. This ensures that the responsible party understands what steps need to be taken to bring the property into compliance.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 109.3 (Notice of Violation) IFC 109.3 requires that any notice of violation must include a description of the violation and the necessary corrective action.
The intent is to provide clear guidance on how to remedy the issue to meet fire safety standards.
2. NFPA 1 - Fire Code (2021 Edition) - Section 1.7.6 (Enforcement and Documentation of Violations) NFPA 1, Section 1.7.6.1 states that violation reports must specify the corrective action required to comply with the fire code.
Detailed Explanation of Answer Choices:
Option A (Incorrect): While a reinspection date may be provided, it is not a mandatory component of an inspection report for code violations.
Option B (Incorrect): A mandatory court date is not always required; enforcement varies depending on jurisdiction and severity of the violation.
Option C (Correct): Recommended corrective action is required in all violation reports as per IFC 109.3 and NFPA 1.7.6.1.
Option D (Incorrect): Potential fines for noncompliance are determined separately and are not necessarily included in the initial violation report.
Thus, the correct and verified answer is: C. Recommended corrective action.
NEW QUESTION # 86
Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds
___ lb.
Answer: B
Explanation:
Refrigeration systems and units are regulated under IFC 2021, Section 605 - Refrigeration Equipment, and the requirement for emergency signs, charts, and labels is tied to the NFPA 704 Hazardous Materials Identification System.
IFC 2021, Section 605.12.3 - Signage for Refrigeration Systems:
States that approved emergency signs, charts, and labels must be provided when the refrigerant quantity exceeds 220 pounds for Group A1 refrigerants.
Definition of Group A1 Refrigerants (Low Toxicity, Low Flammability):
Examples include R-134a, R-410A, and R-22, which are commonly used in commercial and industrial HVAC systems.
Why Other Options Are Incorrect?
A: 30 lb. - Too low; labeling requirements do not apply at this threshold.
B: 100 lb. - Incorrect; the IFC requirement specifies 220 lb.
C: 200 lb. - Close, but still below the 220 lb. threshold.
NEW QUESTION # 87
Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with
Answer: B
Explanation:
Foamed plastics or materials containing foamed plastics used for stage scenery must meet strict fire performance requirements to prevent rapid flame spread and fire hazards in assembly occupancies.
The correct fire test standard for these materials is UL 1975 - Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 807.4.2 (Foamed Plastics for Stage Scenery) IFC 807.4.2 states that foamed plastics used in scenery must be tested and approved per UL 1975 to ensure fire safety.
2. UL 1975 - Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes This standard evaluates the flammability and smoke production of foamed plastics used in decorative applications, including stage scenery.
Detailed Explanation of Answer Choices:
Option A (Correct): UL 1975 is the required test standard for foamed plastics used in stage scenery, ensuring compliance with IFC 807.4.2.
Option B (Incorrect): NFPA 11A deals with foam-water fire suppression systems, not foamed plastics for decorative use.
Option C (Incorrect): CPSC 16CFR relates to consumer product safety regulations but does not address fire safety for foamed plastics on stage scenery.
Option D (Incorrect): ASTM D 1784 is a test for rigid PVC plastics and does not apply to foamed plastics used for stage scenery.
Thus, the correct and verified answer is: A. UL 1975.
NEW QUESTION # 88
The minimum allowable distance to a public traffic route for storage of 1,750 lb. of Class 1.3 explosives is
___ ft.
Answer: C
Explanation:
Reference to Explosive Storage Regulations:
The International Fire Code (IFC 2021), Section 5604 and NFPA 495 (Explosive Materials Code) regulate the storage distances for Class 1.3 explosives (which include low explosives such as propellants and display fireworks).
Table 5604.5.2(3) of the IFC provides minimum separation distances between explosives storage and public traffic routes based on the weight of the explosives.
Determining the Correct Distance:
According to IFC Table 5604.5.2(3), for 1,750 lb. of Class 1.3 explosives, the minimum separation distance from a public traffic route is 115 feet.
Clarification of Incorrect Answer Choices:
A: 50 ft. # Incorrect
50 feet is too close and does not meet the safety requirements for explosive storage.
B: 75 ft. # Incorrect
75 feet is insufficient based on IFC and NFPA separation tables.
D: 150 ft. # Incorrect
While more distance is safer, the minimum requirement is 115 feet, making 150 feet unnecessary per code.
Conclusion:
The correct and verified answer is C (115 feet) based on IFC Table 5604.5.2(3) and NFPA 495 requirements for Class 1.3 explosives storage near public traffic routes.
NEW QUESTION # 89
......
As we all, having a general review of what you have learnt is quite important, it will help you master the knowledge well. Fire-Inspector-II Online test engine has testing history and performance review, and you can have a review through this version. In addition, Fire-Inspector-II Online test engine supports all web browsers and Android and iOS etc. Fire-Inspector-II Exam Materials of us offer you free demo to have a try before buying Fire-Inspector-II training materials, so that you can have a deeper understanding of what you are going to buy. You can receive your downloading link and password within ten minutes, so that you can begin your study right away.
Fire-Inspector-II New Questions: https://www.it-tests.com/Fire-Inspector-II.html
International Code Council Exam Fire-Inspector-II Overviews Study Guides, Audio Exams, Preparation Labs and Hard Copies are not covered by Guarantee policy, When you are preparing the contest which our Fire-Inspector-II study guide aims at, you must have a job or something else to do on your hand, Systematic study, Both of them can help you quickly master the knowledge about the Fire Inspector certification exam, and will help you pass the Fire-Inspector-II real exam easily, International Code Council Exam Fire-Inspector-II Overviews The science and technology are changing with each passing day, and our company is not an exception.
The `log_message` method appends a string to its argument, which in turn affects Fire-Inspector-II New Questions the `home` variable as well, Exploring the New Home Page, Study Guides, Audio Exams, Preparation Labs and Hard Copies are not covered by Guarantee policy.
When you are preparing the contest which our Fire-Inspector-II Study Guide aims at, you must have a job or something else to do on your hand, Systematic study, Both of them can help you quickly master the knowledge about the Fire Inspector certification exam, and will help you pass the Fire-Inspector-II real exam easily.
The science and technology are changing Fire-Inspector-II with each passing day, and our company is not an exception.